Technical Specifications:
| Specifications | Value |
| Mixing ratio (A:B) | 1:1 by weight |
| Hardness | 30 ± 2 Shore A |
| Viscosity (per component) | 20,000 ± 1,000 cps |
| Working time (at 25°C) | 30–40 minutes |
| Time to full cure (at 25°C) | 4–6 hours |
| Tensile Strength | 4.5 MPa |
| Tensile Strength | >17 kN/m |
| Elongation at break | ≥ 500% |
| Shrinkage | ≤ 0.1% |
| Color | Translucent |
Workflow:
- Preparation: The process is most effective at room temperature (20–25°C). The sample and mixing vessels must be completely clean, dry, and free of grease or dust.
- Dosing: Dosing is performed using an electronic scale. Equal amounts of Part A and Part B are measured by WEIGHT, in a 1:1 ratio.
- Mixing: Combine the two components in a clean container. Stir the mixture thoroughly for 3–5 minutes until a homogeneous solution is achieved. It is recommended to scrape the sides and bottom of the container thoroughly while stirring to ensure complete mixing.
- Vacuuming (Recommended Step): To achieve a casting free of air bubbles, it is recommended that the mixture be vacuumed. The procedure lasts 5–10 minutes, until air stops being released from the mixture.
- Pouring: Pour the silicone slowly in a thin stream, starting from the lowest point of the casting box. This method helps residual air escape and prevents the formation of bubbles.
- Curing: The mold takes 4–6 hours to fully cure at room temperature (about 25°C). Working at lower temperatures prolongs this process. Curing can be accelerated by moderate heating (e.g., up to 50°C) after the silicone has been poured into the mold.
Important Information and Safety Precautions:
Risk of inhibition (failure to cure): Platinum-cured silicones are extremely sensitive to certain substances that can halt the chemical reaction. Therefore, during use, avoid contact between the silicone (in liquid form) or the tools and:
- Tin (found in condensation silicones)
- Sulfur (found in some types of modeling clay and latex gloves)
- Amines, amides, and ammonia
- Some adhesives (such as cyanoacrylate adhesives—”Kapchitsa”)
- Strong Acids and Bases
If there is any doubt about the purity of the materials, a small compatibility test can be performed.
Contents of the set and storage:
- Contents: 1 x Bottle of Part A, 1 x Bottle of Part B (1000 g + 1000 g)
- Storage: Store in a cool, dry place, away from direct sunlight, in tightly sealed containers.











Reviews